If Dir(strPubImagePath, vbDirectory) = "" Then
  MsgBox "错误:初始化图象资料夹不存在,请在参数表中重新设置!", vbCritical, msgAwakeYou
End If
如果 strPubImagePath 是本地路径 判断是很快
如果strPubImagePath 是网络路径 并且不存在这样的路径如(\\192.168.1.10\develop\photo\  网络不上存在这样的一个用户电脑 192.168.1.10)
这是就会出现很慢很慢的情况不知大家有什么好的办法可以解决

解决方案 »

  1.   

    這個問題我也遇到過﹐呵呵﹐
    我是通過腳本ping一下﹐然后執行程序的 "cmd /c ping 192.168.1.10 /n 1"
    記號﹐純vb不會﹐希望高手賜教。
    學習中...............
      

  2.   

    先把PING语言写在BAT中,VB运行程序前先Shell这个BAT一下
      

  3.   

    有个API函数可以检查连通性
      Declare Function WNetAddConnection2 Lib "mpr.dll" Alias _
                        "WNetAddConnection2A" (lpNetResource As NETRESOURCE, _
                        ByVal lpPassword As String, ByVal lpUserName As String, _
                        ByVal dwFlags As Long) As Long
    可以判断是否能够访问网络电脑 
      

  4.   

      Dim fso, msg
      Dim fldr As String
      fldr = "\\192.168.1.10\develop\photo\"
      Set fso = CreateObject("Scripting.FileSystemObject")
      If (fso.FolderExists(fldr)) Then
        msg = fldr & " 存在。"
      Else
        msg = fldr & " 不存在。"
      End If这个倒不太慢,只用了十几秒
      

  5.   

    将下面的代码存为模块,可以检测网络路径的文件及目录是否存在。比较好用。不会卡Private Declare Function GetFileAttributes Lib "kernel32" Alias "GetFileAttributesA" (ByVal lpFileName As String) As Long
    Private Const FILE_ATTRIBUTE_DIRECTORY = &H10Public Function IsFileOk(ByVal szFileName As String) As Boolean
        On Error Resume Next
        Dim ret As Long
        IsFileOk = False
        ret = GetFileAttributes(szFileName)
        If ret = -1 Then Exit Function
        IsFileOk = IIf((ret And FILE_ATTRIBUTE_DIRECTORY), False, True)
    End FunctionPublic Function IsFolderOk(ByVal szFolderName As String) As Boolean
        On Error Resume Next
        Dim ret As Long
        IsFolderOk = False
        ret = GetFileAttributes(szFolderName)
        If ret = -1 Then Exit Function
        IsFolderOk = IIf((ret And FILE_ATTRIBUTE_DIRECTORY), True, False)
    End Function
      

  6.   


    Text1.Text = IsFolderOk("\\192.168.1.10\develop\photo\")
    你自己试一啦!一样是卡得很,和用vbs的那个一样。
      

  7.   


    Dim strPubImagePath As String
    strPubImagePath = "\\127.0.0.1\develop\photo\"
    If Dir(strPubImagePath, vbDirectory) = "" Then
      MsgBox "错误:初始化图象资料夹不存在,请在参数表中重新设置!", vbCritical, msgAwakeYou
    End If试过的,是等了好久后就提示出错了,用本地路径就没问题,是不是DIR函数不支持网络的路径啊?
    楼主的用上面的代码也能正常运行吗?
      

  8.   

    不知道用 Winsock控件 建立连接的方式来确认能不能快些。
      

  9.   

    VB调用SHELL可以做到"Ping"这个指令
      

  10.   

    只要你有访问的权限, 下面代码是实际通过测试的.'添加 Command1  Command2Dim fname$
    Private Sub Command1_Click()
       fname = "\\Gtr-c1c5e1aef88\本地磁盘 (F)\sfx.log"
       MsgBox IIf(Dir(fname) <> "", "文件存在", "文件不存在")
    End SubPrivate Sub Command2_Click()
       fname = "\\Gtr-c1c5e1aef88\本地磁盘 (F)\桌面我的文档"
       MsgBox IIf(Dir(fname, vbDirectory) <> "", "文件夹存在", "文件夹不存在")
    End Sub
      

  11.   

    我想问一下13楼的美女,VB调用SHELL是可以做到"Ping"这个命令,但是程序中我们怎么得到PING的返回结果呢?
      

  12.   

    主要是先拼一下速度就上去了,我也曾经被困惑好久,感觉这个方法比较满意。
    代码全'ping ip的例题.有了这个好快的.    回复内容过长.....倒Option Explicit
    Public Const IP_STATUS_BASE = 11000
    Public Const IP_SUCCESS = 0
    Public Const IP_BUF_TOO_SMALL = (11000 + 1)
    Public Const IP_DEST_NET_UNREACHABLE = (11000 + 2)
    Public Const IP_DEST_HOST_UNREACHABLE = (11000 + 3)
    Public Const IP_DEST_PROT_UNREACHABLE = (11000 + 4)
    Public Const IP_DEST_PORT_UNREACHABLE = (11000 + 5)
    Public Const IP_NO_RESOURCES = (11000 + 6)
    Public Const IP_BAD_OPTION = (11000 + 7)
    Public Const IP_HW_ERROR = (11000 + 8)
    Public Const IP_PACKET_TOO_BIG = (11000 + 9)
    Public Const IP_REQ_TIMED_OUT = (11000 + 10)
    Public Const IP_BAD_REQ = (11000 + 11)
    Public Const IP_BAD_ROUTE = (11000 + 12)
    Public Const IP_TTL_EXPIRED_TRANSIT = (11000 + 13)
    Public Const IP_TTL_EXPIRED_REASSEM = (11000 + 14)
    Public Const IP_PARAM_PROBLEM = (11000 + 15)
    Public Const IP_SOURCE_QUENCH = (11000 + 16)
    Public Const IP_OPTION_TOO_BIG = (11000 + 17)
    Public Const IP_BAD_DESTINATION = (11000 + 18)
    Public Const IP_ADDR_DELETED = (11000 + 19)
    Public Const IP_SPEC_MTU_CHANGE = (11000 + 20)
    Public Const IP_MTU_CHANGE = (11000 + 21)
    Public Const IP_UNLOAD = (11000 + 22)
    Public Const IP_ADDR_ADDED = (11000 + 23)
    Public Const IP_GENERAL_FAILURE = (11000 + 50)
    Public Const MAX_IP_STATUS = 11000 + 50
    Public Const IP_PENDING = (11000 + 255)
    Public Const PING_TIMEOUT = 200
    Public Const WS_VERSION_REQD = &H101
    Public Const WS_VERSION_MAJOR = WS_VERSION_REQD \ &H100 And &HFF&
    Public Const WS_VERSION_MINOR = WS_VERSION_REQD And &HFF&
    Public Const MIN_SOCKETS_REQD = 1
    Public Const SOCKET_ERROR = -1Public Const MAX_WSADescription = 256
    Public Const MAX_WSASYSStatus = 128Public Type ICMP_OPTIONS
        Ttl             As Byte
        Tos             As Byte
        Flags           As Byte
        OptionsSize     As Byte
        OptionsData     As Long
    End TypeDim ICMPOPT As ICMP_OPTIONSPublic Type ICMP_ECHO_REPLY
        Address         As Long
        status          As Long
        RoundTripTime   As Long
        DataSize        As Long
        DataPointer     As Long
        Options         As ICMP_OPTIONS
        Data            As String * 250
    End TypePublic Type HOSTENT
        hName As Long
        hAliases As Long
        hAddrType As Integer
        hLen As Integer
        hAddrList As Long
    End TypePublic Type WSADATA
        wVersion As Integer
        wHighVersion As Integer
        szDescription(0 To MAX_WSADescription) As Byte
        szSystemStatus(0 To MAX_WSASYSStatus) As Byte
        wMaxSockets As Long
        wMaxUDPDG As Long
        dwVendorInfo As Long
    End TypePublic Declare Function IcmpCreateFile Lib "icmp.dll" () As Long
    Public Declare Function IcmpCloseHandle Lib "icmp.dll" (ByVal IcmpHandle As Long) As Long
    Public Declare Function IcmpSendEcho Lib "icmp.dll" (ByVal IcmpHandle As Long, ByVal DestinationAddress As Long, ByVal RequestData As String, ByVal RequestSize As Long, ByVal RequestOptions As Long, ReplyBuffer As ICMP_ECHO_REPLY, ByVal ReplySize As Long, ByVal Timeout As Long) As Long
    Public Declare Function WSAGetLastError Lib "WSOCK32.DLL" () As Long
    Public Declare Function WSAStartup Lib "WSOCK32.DLL" (ByVal wVersionRequired As Long, lpWSADATA As WSADATA) As Long
    Public Declare Function WSACleanup Lib "WSOCK32.DLL" () As Long
    Public Declare Function gethostname Lib "WSOCK32.DLL" (ByVal szHost As String, ByVal dwHostLen As Long) As Long
    Public Declare Sub RtlMoveMemory Lib "kernel32" (hpvDest As Any, ByVal hpvSource As Long, ByVal cbCopy As Long)
    Public Function GetStatusCode(status As Long) As String
       Dim msg As String
       Select Case status
          Case IP_SUCCESS:               msg = "ip success"
          Case IP_BUF_TOO_SMALL:         msg = "ip buf too_small"
          Case IP_DEST_NET_UNREACHABLE:  msg = "ip dest net unreachable"
          Case IP_DEST_HOST_UNREACHABLE: msg = "ip dest host unreachable"
          Case IP_DEST_PROT_UNREACHABLE: msg = "ip dest prot unreachable"
          Case IP_DEST_PORT_UNREACHABLE: msg = "ip dest port unreachable"
          Case IP_NO_RESOURCES:          msg = "ip no resources"
          Case IP_BAD_OPTION:            msg = "ip bad option"
          Case IP_HW_ERROR:              msg = "ip hw_error"
          Case IP_PACKET_TOO_BIG:        msg = "ip packet too_big"
          Case IP_REQ_TIMED_OUT:         msg = "ip req timed out"
          Case IP_BAD_REQ:               msg = "ip bad req"
          Case IP_BAD_ROUTE:             msg = "ip bad route"
          Case IP_TTL_EXPIRED_TRANSIT:   msg = "ip ttl expired transit"
          Case IP_TTL_EXPIRED_REASSEM:   msg = "ip ttl expired reassem"
          Case IP_PARAM_PROBLEM:         msg = "ip param_problem"
          Case IP_SOURCE_QUENCH:         msg = "ip source quench"
          Case IP_OPTION_TOO_BIG:        msg = "ip option too_big"
          Case IP_BAD_DESTINATION:       msg = "ip bad destination"
          Case IP_ADDR_DELETED:          msg = "ip addr deleted"
          Case IP_SPEC_MTU_CHANGE:       msg = "ip spec mtu change"
          Case IP_MTU_CHANGE:            msg = "ip mtu_change"
          Case IP_UNLOAD:                msg = "ip unload"
          Case IP_ADDR_ADDED:            msg = "ip addr added"
          Case IP_GENERAL_FAILURE:       msg = "ip general failure"
          Case IP_PENDING:               msg = "ip pending"
          Case PING_TIMEOUT:             msg = "ping timeout"
          Case Else:                     msg = "unknown  msg returned"
       End Select
       GetStatusCode = CStr(status) & "   [ " & msg & " ]"
    End Function
    Public Function HiByte(ByVal wParam As Long) As Integer
        HiByte = wParam \ &H100 And &HFF&
    End Function
    Public Function LoByte(ByVal wParam As Long) As Integer
        LoByte = wParam And &HFF&
    End Function
    Public Function Ping(szAddress As String, ECHO As ICMP_ECHO_REPLY) As Long
        Dim hPort As Long
        Dim dwAddress As Long
        Dim sDataToSend As String
        Dim iOpt As Long
        sDataToSend = "Echo This"
        dwAddress = AddressStringToLong(szAddress)
        hPort = IcmpCreateFile()
        If IcmpSendEcho(hPort, dwAddress, sDataToSend, Len(sDataToSend), 0, ECHO, Len(ECHO), PING_TIMEOUT) Then
            '如果ping成功,状态返回0。
             Ping = ECHO.RoundTripTime
        Else
            Ping = ECHO.status * -1
        End If
        Call IcmpCloseHandle(hPort)
    End Function
       Function AddressStringToLong(ByVal tmp As String) As Long
        Dim i As Integer
        Dim parts(1 To 4) As String
        i = 0
        '转换IP地址
        While InStr(tmp, ".") > 0
            i = i + 1
            parts(i) = Mid(tmp, 1, InStr(tmp, ".") - 1)
            tmp = Mid(tmp, InStr(tmp, ".") + 1)
      

  13.   

        Wend
        i = i + 1
        parts(i) = tmp
        If i <> 4 Then
            AddressStringToLong = 0
            Exit Function
        End If
        AddressStringToLong = Val("&H" & Right("00" & Hex(parts(4)), 2) & Right("00" & Hex(parts(3)), 2) & Right("00" & Hex(parts(2)), 2) & Right("00" & Hex(parts(1)), 2))
    End Function
    Public Sub SocketsCleanup()
        Dim X As Long
        '关闭Sockets
        X = WSACleanup()
        If X <> 0 Then
            MsgBox "Windows Sockets error " & Trim$(Str$(X)) & " occurred in Cleanup.", vbExclamation
        End If
    End Sub
    Public Function SocketsInitialize() As Boolean
        Dim WSAD As WSADATA
        Dim X As Integer
        Dim szLoByte As String
        Dim szHiByte As String
        Dim szBuf As String
        '初始化Socket
        X = WSAStartup(WS_VERSION_REQD, WSAD)
        If X <> 0 Then
            MsgBox "Windows Sockets for 32 bit Windows " & "environments is not successfully responding."
            Exit Function
        End If
        If LoByte(WSAD.wVersion) < WS_VERSION_MAJOR Or (LoByte(WSAD.wVersion) = WS_VERSION_MAJOR And HiByte(WSAD.wVersion) < WS_VERSION_MINOR) Then
            szHiByte = Trim$(Str$(HiByte(WSAD.wVersion)))
            szLoByte = Trim$(Str$(LoByte(WSAD.wVersion)))
            szBuf = "Windows Sockets Version " & szLoByte & "." & szHiByte
            szBuf = szBuf & " is not supported by Windows " & "Sockets for 32 bit Windows environments."
            MsgBox szBuf, vbExclamation
            Exit Function
        End If
        If WSAD.wMaxSockets < MIN_SOCKETS_REQD Then
            szBuf = "This application requires a minimum of " & Trim$(Str$(MIN_SOCKETS_REQD)) & " supported sockets."
            MsgBox szBuf, vbExclamation
            Exit Function
        End If
        SocketsInitialize = True
    End Function
    '--------------------------------------
    Private Sub Command1_Click()
        Dim ECHO As ICMP_ECHO_REPLY
        Dim pos As Integer
        If SocketsInitialize() Then
            'ping地址
            Call Ping((Text2), ECHO)
            '显示ping结果
            Text1(0) = GetStatusCode(ECHO.status)
            Text1(1) = ECHO.RoundTripTime & " ms"
            Text1(2) = ECHO.DataSize & " bytes"
            If Left$(ECHO.Data, 1) <> Chr$(0) Then
                pos = InStr(ECHO.Data, Chr$(0))
                Text1(3) = Left$(ECHO.Data, pos - 1)
            End If
            Text1(4) = ECHO.DataPointer
            SocketsCleanup
        End If
    End SubPrivate Sub Form_Load()End Sub
      

  14.   


    大哥,帮帮忙看看好吗?
    怎么没人回贴。
    http://topic.csdn.net/u/20080524/10/acbdcfbc-25a6-4531-b595-0249428de888.html
      

  15.   

    楼主,咱俩现在是一个问题呀,不知道你的解决了没有,如果解决了,千万要告诉我一声呀。我的EMAIL:
    [email protected]